Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.693
Filtrar
1.
BMC Anesthesiol ; 23(1): 8, 2023 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-36609229

RESUMO

BACKGROUND: Blood pressure measurement is an essential element during intraoperative patient management. However, errors caused by changes in transducer levels can occur during surgery. METHODS: This single center, prospective, observational study enrolled 25 consecutive patients scheduled for elective cardiac surgery with invasive arterial and central venous pressure (CVP) monitoring. Hydrostatic pressures caused by level differences (leveling pressure) between a reference point (on the center of the left biceps brachii muscle) and the transducers (fixed on the right side of the operating table) for arterial and central lines were continuously measured using a leveling transducer. Adjusted pressures were calculated as measured pressure - leveling pressure. Hypotension (mean arterial pressure < 80, <70, and < 60 mmHg), and CVP (< 6, ≥6 and < 15, or ≥ 15 mmHg) and pulmonary artery pressure (PAP, mean > 20 mmHg) levels were determined using unadjusted and adjusted pressures. RESULTS: Twenty-two patients were included in the analysis. Leveling pressure ≥ 3 mmHg and ≥ 5 mmHg observed at 46.0 and 18.7% of pooled data points, respectively. Determinations of hypotension using unadjusted and adjusted pressures showed disagreements ranging from 3.3 to 9.4% depending on the cutoffs. Disagreements in defined levels of CVP and PAP were observed at 23.0 and 17.2% of the data points, respectively. CONCLUSIONS: The errors in pressure measurement due to changes in transducer level were not trivial and caused variable disagreements in the determination of MAP, CVP, and PAP levels. To prevent distortions in intraoperative hemodynamic management, strategies should be sought to minimize or adjust for these errors in clinical practice. TRIAL REGISTRATION: cris.nih.go.kr (KCT0006510).


Assuntos
Procedimentos Cirúrgicos Cardíacos , Hipotensão , Humanos , Adulto , Pressão Venosa Central/fisiologia , Transdutores de Pressão , Estudos Prospectivos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Hipotensão/diagnóstico
2.
Nat Biomed Eng ; 6(10): 1092-1104, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35314802

RESUMO

The evaluation of the tone and contractile patterns of the gastrointestinal (GI) tract via manometry is essential for the diagnosis of GI motility disorders. However, manometry is expensive and relies on complex and bulky instrumentation. Here we report the development and performance of an inexpensive and easy-to-manufacture catheter-like device for capturing manometric data across the dynamic range observed in the human GI tract. The device, which we designed to resemble the quipu-knotted strings used by Andean civilizations for the capture and transmission of information-consists of knotted piezoresistive pressure sensors made by infusing a liquid metal (eutectic gallium-indium) through thin silicone tubing. By exploring a range of knotting configurations, we identified optimal design schemes that led to sensing performances comparable to those of commercial devices for GI manometry, as we show for the sensing of GI motility in multiple anatomic sites of the GI tract of anaesthetized pigs. Disposable and customizable piezoresistive catheters may broaden the use of GI manometry in low-resource settings.


Assuntos
Gálio , Silicones , Humanos , Suínos , Animais , Transdutores de Pressão , Índio , Manometria
3.
Sensors (Basel) ; 22(5)2022 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-35270877

RESUMO

Timely and reliable identification of control phases is functional to the control of a powered robotic lower-limb prosthesis. This study presents a commercial energy-store-and-release foot prosthesis instrumented with a multimodal sensory system comprising optoelectronic pressure sensors (PS) and IMU. The performance was verified with eight healthy participants, comparing signals processed by two different algorithms, based on PS and IMU, respectively, for real-time detection of heel strike (HS) and toe-off (TO) events and an estimate of relevant biomechanical variables such as vertical ground reaction force (vGRF) and center of pressure along the sagittal axis (CoPy). The performance of both algorithms was benchmarked against a force platform and a marker-based stereophotogrammetric motion capture system. HS and TO were estimated with a time error lower than 0.100 s for both the algorithms, sufficient for the control of a lower-limb robotic prosthesis. Finally, the CoPy computed from the PS showed a Pearson correlation coefficient of 0.97 (0.02) with the same variable computed through the force platform.


Assuntos
Procedimentos Cirúrgicos Robóticos , Fenômenos Biomecânicos , , Marcha , Humanos , Transdutores de Pressão
5.
J Trauma Acute Care Surg ; 92(4): 729-734, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34789704

RESUMO

BACKGROUND: Management of noncompressible truncal hemorrhage using resuscitative endovascular balloon occlusion of the aorta (REBOA) requires arterial pressure monitoring that can be logistically challenging in austere or emergency settings. Novel pressure transducer devices such as the Centurion Compass device (CD) (Medline, Northfield, IL) offer an alternative to traditional monitoring systems. We sought to assess the feasibility of maintaining permissive hypotension during intermittent REBOA in a porcine model guided by CD monitoring. METHODS: Eight Yorkshire swine underwent 20% hemorrhage with an uncontrolled iliofemoral vascular injury. Time-based intermittent zone 1 REBOA was performed with volume-based resuscitation to maintain permissive hypotension. Proximal mean arterial pressures (MAPs) from a carotid arterial line (AL) were obtained and compared with CD readings from the proximal REBOA port. The operator was blinded to AL MAP, and the REBOA was managed with exclusively the CD. RESULTS: Mean survival time was 100 minutes (range, 41-120 minutes) from injury. Arterial line and CD measurements were closely correlated (r = 0.94, p < 0.001). Bland-Altman analysis for comparison of clinical measurements demonstrated a mean difference of 6 mm Hg (95% confidence interval, -22 to 34 mm Hg) for all MAPs, with a mean difference of 3 mm Hg (95% confidence interval, -6 to 12 mm Hg) in a clinically relevant MAP of <65 mm Hg subset. CONCLUSION: The CD represents a miniaturized and portable arterial pressure monitor that provides an accurate alternative to logistically burdensome AL monitoring to guide REBOA use. The device is highly accurate even at hypotensive pressures and can be used to guide intermittent REBOA strategies.


Assuntos
Oclusão com Balão , Hipotensão , Animais , Aorta , Hemorragia/etiologia , Hemorragia/terapia , Suínos , Transdutores de Pressão
6.
J Vasc Surg ; 75(3): 939-949.e1, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34601043

RESUMO

OBJECTIVE: The indication of percutaneous renal transluminal angioplasty (PTRA) in fibromuscular dysplasia (FMD) is mainly based on renal artery stenosis (RAS) due to atherosclerosis criteria, which are not specific to FMD. Consequently, the selection of patients who could benefit from this treatment and its effectiveness remain uncertain. The aims of this study were to: (1) report the effects of PTRA guided by trans-stenotic pressure measurements on hypertension 7 months after treatment; (2) assess the impact of pressure measurement to guide treatment efficacy in comparison to visual angiographic parameters; and (3) evaluate the reproducibility and accuracy of the stenosis measurement using a 4F catheter in comparison to a pressure guidewire. METHODS: This prospective multi-centric study analyzed 24 patients with hypertension with RAS due to FMD that required PTRA. Clinical, duplex ultrasound, and angiographic indices were collected, and patients were followed up for 7 months (±1 month). Angiographic indices were measured twice both by a pressure guidewire and a 4F catheter. Assessment of procedural and clinical success of angioplasty was performed for all patients. RESULTS: Twenty-three patients (96%) had procedural success (considered as a post-PTRA translesional systolic gradient ≤10 mmHg or reduced by at least 80%) with a significant decrease in the systolic gradient after angioplasty (26.50 mmHg; [interquartile range, 16.75-38.75] vs 0.00 [interquartile range, 0.00-2.00]; P < .01). Three patients (12%) had complications, including two renal artery dissections and one partial renal infarction. Twenty-one patients (88%) were clinical responders to angioplasty at follow-up. Visual stenosis assessment showed a poor correlation with systolic gradient measurement before and after PTRA (R from -0.05 to 0.41; P = 0.06-0.82). High correlations were found between pressure measurements made by a 4F catheter and guidewire (R from 0.64 to 0.89; P ≤ .003). CONCLUSIONS: In patients selected by clinical indicators and duplex ultrasound, reaching a translesional systolic gradient ≤10 mmHg or reduced by at least 80% after angioplasty, promotes a high success rate for PTRA in hypertension due to FMD RAS.


Assuntos
Angioplastia com Balão , Pressão Arterial , Displasia Fibromuscular/terapia , Hipertensão Renovascular/terapia , Obstrução da Artéria Renal/terapia , Artéria Renal/fisiopatologia , Adulto , Angioplastia com Balão/efeitos adversos , Determinação da Pressão Arterial/instrumentação , Angiografia por Tomografia Computadorizada , Feminino , Displasia Fibromuscular/complicações , Displasia Fibromuscular/diagnóstico , Displasia Fibromuscular/fisiopatologia , França , Humanos , Hipertensão Renovascular/diagnóstico , Hipertensão Renovascular/etiologia , Hipertensão Renovascular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Estudos Prospectivos , Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/diagnóstico , Obstrução da Artéria Renal/etiologia , Obstrução da Artéria Renal/fisiopatologia , Fatores de Tempo , Transdutores de Pressão , Resultado do Tratamento , Ultrassonografia Doppler em Cores , Dispositivos de Acesso Vascular
7.
J Orthop Surg Res ; 16(1): 407, 2021 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-34162413

RESUMO

BACKGROUND: In tibial plateau fractures, the posterolateral segment of the tibia plateau is frequently affected and challenging to treat. Although there are many surgical approaches and fixation methods for the treatment of these fractures, all of these methods have limitations. We designed a new rotational support plate (RSP) and a special pressurizer that can fix the fracture directly via the anterolateral approach. This method is advantageous because it leads to little trauma, involves a simple operation, and has a reliable fixation effect. This study details the technique of treating these fractures with the RSP and special pressurizer and provides the outcomes. METHODS: From May 2016 to January 2019, the data of 12 patients with posterolateral tibial plateau fractures treated with the RSP and special pressurizer in our hospital were retrospectively analyzed. Postoperative rehabilitation was advised, knee X-rays were taken at follow-ups, and fracture healing, complications, and knee range of motion were assessed. The Hospital for Special Surgery (HSS) knee score and Knee Injury and Osteoarthritis Outcome Score (KOOS) were used to evaluate knee function at the last follow-up. RESULTS: The average follow-up time of all patients was 16.5 months (range, 12-25 months). The average bony union time was 3.2 months (range, 3-4.5 months). At the last follow-up, the average knee range of motion was 138° (range, 107-145°). The average HSS score was 91 (range, 64-98). The average KOOS Symptoms score was 90 (range, 75-96). The average KOOS Pain score was 91 (range, 72-97). The average KOOS ADL score was 91 (range, 74-97). The average KOOS sport/recreation score was 83 (range, 70-90). The average KOOS QOL score was 88 (range, 69-93). Skin necrosis, incision infections, and fixation failure did not occur during the follow-up period. CONCLUSIONS: With our newly designed RSP and special pressurizer, posterolateral tibial plateau fractures can be easily and effectively reduced and fixed through the anterolateral approach, which serves as a novel treatment for posterolateral tibial plateau fractures.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Fixação de Fratura/instrumentação , Fraturas da Tíbia/cirurgia , Transdutores de Pressão , Adulto , Idoso , Feminino , Fixação de Fratura/métodos , Fixação Interna de Fraturas/métodos , Consolidação da Fratura , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Pressão , Amplitude de Movimento Articular , Estudos Retrospectivos , Fraturas da Tíbia/fisiopatologia , Resultado do Tratamento
8.
West J Emerg Med ; 22(3): 775-781, 2021 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-34125060

RESUMO

INTRODUCTION: Ultrasound hypotension protocols (UHP) involve imaging multiple body areas, each with different transducers and imaging presets. The time for task switching between presets and transducers to perform an UHP has not been previously studied. A novel hand-carried ultrasound (HCU) has been developed that uses a multifrequency single transducer to image areas of the body (lung, heart, abdomen, superficial) that would typically require three transducers using a traditional cart-based ultrasound (CBU) system. Our primary aim was to compare the time to complete UHPs with a single transducer HCU to a multiple transducer CBU. METHODS: We performed a randomized, crossover feasibility trial in the emergency department of an urban, safety-net hospital. This was a convenience sample of non-hypotensive emergency department patients presenting during a two-month period of time. Ultrasound hypotension protocols were performed by emergency physicians (EP) on patients using the HCU and the CBU. The EPs collected UHP views in sequential order using the most appropriate transducer and preset for the area/organ to be imaged. Time to complete each view, time for task switching, total time to complete the examination, and image diagnostic quality were recorded. RESULTS: A total of 29 patients were scanned by one of eight EPs. When comparing the HCU to the CBU, the median time to complete the UHP was 4.3 vs 8.5 minutes (P <0.0001), respectively. When the transport and plugin times were excluded, the median times were 4.1 vs 5.8 minutes (P <0.0001), respectively. There was no difference in the diagnostic quality of images obtained by the two devices. CONCLUSION: Ultrasound hypotension protocols were performed significantly faster using the single transducer HCU compared to a multiple transducer CBU with no difference in the number of images deemed to be diagnostic quality.


Assuntos
Hipotensão/diagnóstico por imagem , Transdutores de Pressão/normas , Ultrassonografia/métodos , Adulto , Idoso , Estudos Cross-Over , Serviço Hospitalar de Emergência , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
J Stroke Cerebrovasc Dis ; 30(7): 105826, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33932749

RESUMO

OBJECTIVES: To survey recent advances in acute stroke symptom automatic detection and Emergency Medical Systems (EMS) alerting by mobile health technologies. MATERIALS AND METHODS: Narrative review RESULTS: Delayed activation of EMS for stroke symptoms by patients and witnesses deprives patients of rapid access to brain-saving therapies and occurs due to public unawareness of stroke features, cognitive and motor deficits produced by the stroke itself, and sleep onset. A promising emerging approach to overcoming the inherent biologic constraints of patient capacity to self-detect and respond to stroke symptoms is continuous monitoring by mobile health technologies with wireless sensors and artificial intelligence recognition systems. This review surveys 11 sensing technologies - accelerometers, gyroscopes, magnetometers, pressure sensors, touch screen and keyboard input detectors, artificial vision, and artificial hearing; and 10 consumer device form factors in which they are increasingly implemented: smartphones, smart speakers, smart watches and fitness bands, smart speakers/voice assistants, home health robots, smart clothing, smart beds, closed circuit television, smart rings, and desktop/laptop/tablet computers. CONCLUSIONS: The increase in computing power, wearable sensors, and mobile connectivity have ushered in an array of mobile health technologies that can transform stroke detection and EMS activation. By continuously monitoring a diverse range of biometric parameters, commercially available devices provide the technologic capability to detect cardinal language, motor, gait, and sensory signs of stroke onset. Intensified translational research to convert the promise of these technologies to validated, accurate real-world deployments are an important next priority for stroke investigation.


Assuntos
Computadores de Mão , Serviços Médicos de Emergência , Aplicativos Móveis , Monitorização Ambulatorial/instrumentação , Acidente Vascular Cerebral/diagnóstico , Telemedicina/instrumentação , Transdutores de Pressão , Dispositivos Eletrônicos Vestíveis , Tecnologia sem Fio/instrumentação , Inteligência Artificial , Tomada de Decisão Clínica , Diagnóstico Precoce , Monitores de Aptidão Física , Humanos , Valor Preditivo dos Testes , Prognóstico , Smartphone , Acidente Vascular Cerebral/fisiopatologia , Acidente Vascular Cerebral/terapia , Fatores de Tempo , Tempo para o Tratamento
10.
Physiol Rep ; 9(8): e14831, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33938126

RESUMO

Respiratory pressure responses to cervical magnetic stimulation are important measurements in monitoring the mechanical function of the respiratory muscles. Pressures can be measured using balloon catheters or a catheter containing integrated micro-transducers. However, no research has provided a comprehensive analysis of their pressure measurement characteristics. Accordingly, the aim of this study was to provide a comparative analysis of these characteristics in two separate experiments: (1) in vitro with a reference pressure transducer following a controlled pressurization; and (2) in vivo following cervical magnetic stimulations. In vitro the micro-transducer catheter recorded pressure amplitudes and areas which were in closer agreement to the reference pressure transducer than the balloon catheter. In vivo there was a main effect for stimulation power and catheter for esophageal (Pes ), gastric (Pga ), and transdiaphragmatic (Pdi ) pressure amplitudes (p < 0.001) with the micro-transducer catheter recording larger pressure amplitudes. There was a main effect of stimulation power (p < 0.001) and no main effect of catheter for esophageal (p = 0.481), gastric (p = 0.923), and transdiaphragmatic (p = 0.964) pressure areas. At 100% stimulator power agreement between catheters for Pdi amplitude (bias =6.9 cmH2 O and LOA -0.61 to 14.27 cmH2 O) and pressure areas (bias = -0.05 cmH2 O·s and LOA -1.22 to 1.11 cmH2 O·s) were assessed. At 100% stimulator power, and compared to the balloon catheters, the micro-transducer catheter displayed a shorter 10-90% rise time, contraction time, latency, and half-relaxation time, alongside greater maximal rates of change in pressure for esophageal, gastric, and transdiaphragmatic pressure amplitudes (p < 0.05). These results suggest that caution is warranted if comparing pressure amplitude results utilizing different catheter systems, or if micro-transducers are used in clinical settings while applying balloon catheter-derived normative values. However, pressure areas could be used as an alternative point of comparison between catheter systems.


Assuntos
Cateteres/efeitos adversos , Transdutores de Pressão/efeitos adversos , Adulto , Cateteres/normas , Esôfago/fisiologia , Feminino , Humanos , Masculino , Manometria/instrumentação , Pressão , Testes de Função Respiratória/instrumentação , Músculos Respiratórios/fisiologia , Transdutores de Pressão/normas
11.
J Sports Sci ; 39(11): 1236-1276, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33588689

RESUMO

The present review aims at providing researchers and practitioners with a holistic overview of technology-based methods for the assessment of fine and gross motor skill in children. We conducted a search of electronic databases using Web of Science, PubMed and Google Scholar, including studies published up to March 2020, that assessed fine and/or gross motor skills, and utilized technological assessment of varying study design. A total of 739 papers were initially retrieved, and after title/abstract screening, removal of duplicates, and full-text screening, 47 were included. Results suggest that motor skills can be quantitatively estimated using objective methods based on a wearable- and/or laboratory-based technology, for typically developing (TD) and non-TD children. Fine motor skill assessment solutions were; force transducers, instrumented tablets and pens, surface electromyography, and optoelectronic systems. Gross motor skill assessment solutions were; inertial measurements units, optoelectronic systems, baropodometric mats, and force platforms. This review provides a guide in identifying and evaluating the plethora of available technological solutions to motor skill assessment. Although promising, there is still a need for large-scale studies to validate these approaches in terms of accuracy, repeatability, and usability, where interdisciplinary collaborations between researchers and practitioners and transparent reporting practices should be advocated.


Assuntos
Destreza Motora/fisiologia , Acelerometria/instrumentação , Adolescente , Criança , Desenvolvimento Infantil/fisiologia , Pré-Escolar , Deficiências do Desenvolvimento/fisiopatologia , Eletromiografia/métodos , Feminino , Previsões , Força da Mão , Saúde Holística , Humanos , Magnetometria/instrumentação , Masculino , Atividade Motora , Fenômenos Fisiológicos Musculoesqueléticos , Transdutores de Pressão , Dispositivos Eletrônicos Vestíveis , Redação
12.
Muscle Nerve ; 63(3): 327-335, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33314195

RESUMO

BACKGROUND: Unilateral diaphragmatic paralysis (UDP) has major clinical and etiological implications and, therefore, is important to diagnose. Lung function tests and invasive transdiaphragmatic pressure (Pdi) measurements are widely used to this end but, contrary to phrenic nerve conduction study (NCS), they require volitional maneuvers and/or may be poorly tolerated by patients. The purpose of this study was to compare the diagnostic accuracy of Pdi and phrenic NCS for UDP. METHODS: We retrospectively reviewed 28 patients with suspected UDP. The diagnosis established during a multidisciplinary meeting was the reference standard. RESULTS: Phrenic NCS correlated well with Pdi (r = 0.82, P < .005), and the two tests showed good agreement (κ = 0.82, P < .005). Phrenic NCS and Pdi measurements both had 95% sensitivity, 87.5% specificity, 95% positive predictive, and 87.5% negative predictive values. CONCLUSIONS: Both tests were highly sensitive and specific. Phrenic NCS measurement is a simple, reproducible, noninvasive method whose results correlate well with Pdi and provide insight into the UDP mechanism. In the most difficult cases, combining lung function tests, respiratory muscle assessments, and phrenic NCS can help to establish the diagnosis.


Assuntos
Eletrodiagnóstico/métodos , Esôfago , Condução Nervosa , Nervo Frênico/fisiopatologia , Pressão , Paralisia Respiratória/diagnóstico , Estômago , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Testes de Função Respiratória , Músculos Respiratórios , Paralisia Respiratória/fisiopatologia , Estudos Retrospectivos , Sensibilidade e Especificidade , Transdutores de Pressão
13.
Anesth Analg ; 132(3): 827-835, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33002924

RESUMO

BACKGROUND: Double-lumen endobronchial tubes (DLTs) are used for one-lung ventilation (OLV) during thoracic surgery. Overinflation into the bronchial cuff causes damage to the tracheobronchial mucosa, whereas underinflation leads to an incomplete collapse of the nonventilated lung or incomplete ventilation of the ventilated lung. However, how to determine the appropriate bronchial cuff volume and pressure during OLV is unclear. The objective of this study is to compare the required bronchial cuff volume for lung separation obtained by 2 different cuff inflation methods under closed- and open-chest conditions. METHODS: A total of 64 patients scheduled to undergo elective thoracic surgery requiring OLV were recruited. Left DLTs were used for both right- and left-sided surgery. The patients were randomly assigned to 1 of 2 inflation-type groups to estimate the bronchial cuff volume. In the capnogram waveform-guided bronchial cuff inflation group (capno group, n = 27), the bronchial cuff was inflated until a capnometer sampling gas containing CO2 from the nonventilated lung displayed a flat line. The corresponding bronchial cuff volume and pressure were then recorded. In the pressure-guided bronchial cuff inflation group (pressure group, n = 29), the bronchial cuff was inflated by a cuff inflator to a pressure of 20 cm H2O. Lung separation was confirmed when a flat line of a capnometer was observed after gas sampling from the nonventilated lung. RESULTS: Under closed-chest conditions, the bronchial cuff sealing volume for the capno group was significantly lower than that for the pressure group (mean [standard deviation {SD}], 1.00 [0.65] mL vs 1.44 [0.59] mL, mean difference, -0.44; 97.5% confidence interval [CI], -0.78 to -0.11; P = .010). Under open-chest conditions, the bronchial cuff sealing volume for the capno group was also significantly lower than that for the pressure group (mean [SD], 0.65 [0.66] mL vs 1.22 [0.45] mL, mean difference, -0.58; 97.5% CI, -0.88 to -0.27; P < .001). CONCLUSIONS: The lowest cuff volume providing an air-tight bronchial seal was obtained by the capnogram waveform-guided bronchial cuff inflation method. Since the cuff volume required to achieve an air-tight seal decreases after opening the chest, readjustment of the bronchial cuff volume to prevent bronchial cuff damage to the tracheobronchial mucosa after opening the chest may be advisable.


Assuntos
Brônquios , Capnografia , Intubação Intratraqueal/instrumentação , Ventilação Monopulmonar/instrumentação , Toracotomia , Transdutores de Pressão , Idoso , Desenho de Equipamento , Feminino , Humanos , Intubação Intratraqueal/efeitos adversos , Japão , Masculino , Pessoa de Meia-Idade , Ventilação Monopulmonar/efeitos adversos , Valor Preditivo dos Testes , Pressão , Estudos Prospectivos , Toracotomia/efeitos adversos , Resultado do Tratamento
14.
Ann Otol Rhinol Laryngol ; 130(2): 167-172, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32680431

RESUMO

PURPOSE: To evaluate endoscopic long-range optical coherence tomography system combined with a pressure sensor to concurrently measure internal nasal valve cross-sectional area and intraluminal pressure. METHODS: A pressure sensor was constructed using an Arduino platform and calibrated using a limiter-controlled vacuum system and industrial absolute pressure gauge. Long-range optical coherence tomography imaging and pressure transduction were performed concurrently in the naris of eight healthy adult subjects during normal respiration and forced inspiration. The internal nasal valve was manually segmented using Mimics software and cross-sectional area was measured. Internal nasal valve cross-sectional area measurements were correlated with pressure recordings. RESULTS: Mean cross-sectional area during forced inspiration was 6.49 mm2. The mean change in pressure between normal respiration and forceful inspiration was 12.27 mmHg. The direct correlation between pressure and cross-sectional area as measured by our proposed system was reproducible among subjects. CONCLUSIONS: Our results demonstrate a direct correlation between internal nasal valve cross-sectional area and nasal airflow during inspiration cycles. Endoscopic long-range optical coherence tomography coupled with a pressure sensor serves as a useful tool to quantify the dynamic behavior of the internal nasal valve.


Assuntos
Cavidade Nasal/diagnóstico por imagem , Cavidade Nasal/fisiologia , Tomografia de Coerência Óptica , Transdutores de Pressão , Feminino , Voluntários Saudáveis , Humanos , Inalação , Masculino , Respiração
15.
J Biomed Mater Res A ; 109(5): 579-589, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32589778

RESUMO

Pulmonary arterial hypertension (PAH) is associated with elevated pulmonary arterial pressure. PAH prognosis remains poor with a 15% mortality rate within 1 year, even with modern clinical management. Previous clinical studies proposed wall shear stress (WSS) to be an important hemodynamic factor affecting cell mechanotransduction, growth and remodeling, and disease progress in PAH. However, WSS in vivo is typically at most 2.5 Pa and a doubt has been cast whether WSS alone can drive disease progress. Furthermore, our current understanding of PAH pathology largely comes from small animals' studies in which caliber enlargement, a hallmark of PAH in humans, is rarely reported. Therefore, a large-animal experiment on pulmonary arteries (PAs) is needed to validate whether increased pressure can induce enlargement of PAs caliber. In this study, we use an inflation testing device to characterize the mechanical behavior, both nonlinear elastic behavior and irreversible damage of porcine arteries. The parameters of elastic behavior are estimated from the inflation test at a low-pressure range before and after over-pressurization. Then, histological images are qualitatively examined for medial and adventitial layers. This study sheds light on the relevance of pressure-induced damage mechanism in human PAH.


Assuntos
Pressão/efeitos adversos , Hipertensão Arterial Pulmonar/fisiopatologia , Artéria Pulmonar/lesões , Animais , Elasticidade , Desenho de Equipamento , Modelos Biológicos , Estresse Mecânico , Suínos , Transdutores de Pressão
16.
J Cardiovasc Transl Res ; 14(2): 283-289, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32495264

RESUMO

Although ex vivo simulation is a valuable tool for surgical optimization, a disease model that mimics human aortic regurgitation (AR) from cusp prolapse is needed to accurately examine valve biomechanics. To simulate AR, four porcine aortic valves were explanted, and the commissure between the two largest leaflets was detached and re-implanted 5 mm lower to induce cusp prolapse. Four additional valves were tested in their native state as controls. All valves were tested in a heart simulator while hemodynamics, high-speed videography, and echocardiography data were collected. Our AR model successfully reproduced cusp prolapse with significant increase in regurgitant volume compared with that of the controls (23.2 ± 8.9 versus 2.8 ± 1.6 ml, p = 0.017). Hemodynamics data confirmed the simulation of physiologic disease conditions. Echocardiography and color flow mapping demonstrated the presence of mild to moderate eccentric regurgitation in our AR model. This novel AR model has enormous potential in the evaluation of valve biomechanics and surgical repair techniques. Graphical Abstract.


Assuntos
Insuficiência da Valva Aórtica/fisiopatologia , Prolapso da Valva Aórtica/fisiopatologia , Valva Aórtica/fisiopatologia , Hemodinâmica , Modelos Cardiovasculares , Animais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Prolapso da Valva Aórtica/diagnóstico por imagem , Fenômenos Biomecânicos , Ecocardiografia Doppler em Cores , Desenho de Equipamento , Técnicas In Vitro , Impressão Tridimensional , Sus scrofa , Técnicas de Sutura , Transdutores de Pressão
17.
Anesth Analg ; 132(2): 556-565, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33323786

RESUMO

BACKGROUND: Nerve damage can occur after peripheral nerve block (PNB). Ultrasound guidance does not eliminate the risk of intraneural injection or nerve injury. Combining nerve stimulation and injection pressure (IP) monitoring with ultrasound guidance has been suggested to optimize needle tip location in PNB. In this prospective observational study, we hypothesized that measured pairs of IP and minimum intensity of stimulation (MIS) might differentiate successive needle tip locations established by high-resolution ultrasound during PNB. METHODS: For this exploratory study, 240 observations for 40 ultrasound-guided PNBs were studied in 28 patients scheduled for orthopedic surgery. During the progression of the needle to the nerve observed by ultrasonography, the IP was measured continuously using a computerized pressure-sensing device with a low flow rate of solution. Stimulation thresholds and electrical impedance were obtained by an impedance analyzer coupled to the nerve stimulator at 6 successive needle positions. The median (quartile) or mean (95% confidence interval [CI]) was reported. A mixed model analysis was used, and the sample was also explored using a classification and regression tree (CART) algorithm. RESULTS: Specific combinations of IP and MIS were measured for subcutaneous, epimysium contact, intramuscular, nerve contact (231 mm Hg [203-259 mm Hg] and 1.70 mA [1.38-2.02 mA]), intraneural location (188 mm Hg [152-224 mm Hg] and 0.58 mA [0.46-0.70 mA]), and subparaneural location (47 mm Hg [41-53 mm Hg] and 1.35 mA [1.09-1.61 mA]). The CART algorithm shows that the optimal subparaneural needle tip position might be defined by the lowest pressure (<81.3 mm Hg) and MIS (<1.5 mA) cutoffs. CONCLUSIONS: Our exploratory study evaluated concepts to generate hypotheses. The combinations of IP and MIS might help the physician during a PNB procedure. A low IP and low MIS might confirm a subparaneural location, and a high IP and a low MIS might be an alert for the intraneural location of the needle tip.


Assuntos
Anestésicos Locais/administração & dosagem , Bloqueio Nervoso , Nervos Periféricos/diagnóstico por imagem , Ultrassonografia de Intervenção , Anestésicos Locais/efeitos adversos , Estimulação Elétrica , Feminino , Humanos , Injeções , Masculino , Pessoa de Meia-Idade , Agulhas , Bloqueio Nervoso/efeitos adversos , Procedimentos Ortopédicos , Pressão , Estudos Prospectivos , Transdutores de Pressão
18.
IEEE Trans Biomed Eng ; 68(3): 747-758, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32780694

RESUMO

In this article, we demonstrate a wireless and passive physiological pressure sensing scheme that utilizes ultrasound imaging of an implantable microfluidic based pressure sensitive transducer. The transducer consists of a sub-mm scale pressure sensitive membrane that covers a reservoir filled with water and is connected to a hydrophobic micro-channel. Applied pressure onto the transducer deflects the membrane and pushes the water from the reservoir into the channel; the water's travelling distance in the channel is a function of the applied pressure, which is quantitatively measured by using a 40 MHz ultrasound imaging system. The sensor presents a linear sensitivity of 42 kPa/mm and a spatial resolution of 1.2 kPa/30 µm in the physiological range of abdominal compartment syndrome. Reliability assessments of the transducer confirm its ability to remain functional after more than 600 cycles of pressure up to 55 kPa over the course of 2 days. Ex vivo experimental results verify the practical capability of the technology to effectively measure pressures under a 15 mm thick porcine skin. It is anticipated that this technology can be applied to a broad range of implantable pressure measurement, by simply tuning the thickness of the thin polydimethylsiloxane membrane and the geometry of the reservoir.


Assuntos
Dispositivos Lab-On-A-Chip , Próteses e Implantes , Animais , Reprodutibilidade dos Testes , Suínos , Transdutores de Pressão , Ultrassom
19.
Anaesthesia ; 76(1): 27-35, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32776518

RESUMO

It is recognised that high-flow nasal therapy can prevent desaturation during airway management. Studies in spontaneously breathing patients show an almost linear relationship between flow rate and positive airway pressure in the nasopharynx. Positive airway pressure has been suggested as one of the possible mechanisms explaining how high-flow nasal therapy works. However, data on pressures generated by high-flow nasal therapy in apnoeic adults under general anaesthesia are absent. This randomised controlled crossover trial investigated airway pressures generated by different flow rates during high-flow nasal therapy in anaesthetised and paralysed apnoeic patients, comparing pressures with closed and open mouths. Following induction of anaesthesia and neuromuscular blockade, a continuous jaw thrust was used to enable airway patency. Airway pressure was measured in the right main bronchus, the middle of the trachea and the pharynx, using a fibreoptically-placed catheter connected to a pressure transducer. Each measurement was randomised with respect to closed or open mouth and different flow rates. Twenty patients undergoing elective surgery were included (mean (SD) age 38 (18) years, BMI 25.0 (3.3) kg.m-2 , nine women, ASA physical status 1 (35%), 2 (55%), 3 (10%). While closed mouths and increasing flow rates demonstrated non-linear increases in pressure, the pressure increase was negligible with an open mouth. Airway pressures remained below 10 cmH2 O even with closed mouths and flow rates up to 80 l.min-1 ; they were not influenced by catheter position. This study shows an increase in airway pressures with closed mouths that depends on flow rate. The generated pressure is negligible with an open mouth. These data question positive airway pressure as an important mechanism for maintenance of oxygenation during apnoea.


Assuntos
Manuseio das Vias Aéreas/métodos , Apneia/terapia , Pressão Positiva Contínua nas Vias Aéreas/métodos , Nasofaringe , Adulto , Pressão do Ar , Anestesia , Estudos Cross-Over , Procedimentos Cirúrgicos Eletivos , Feminino , Tecnologia de Fibra Óptica , Humanos , Masculino , Pessoa de Meia-Idade , Boca , Bloqueio Neuromuscular , Transdutores de Pressão , Resultado do Tratamento , Adulto Jovem
20.
Int J Cardiovasc Imaging ; 37(1): 5-14, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32804319

RESUMO

The effect of hydrostatic pressure on physiological intracoronary measurements is usually ignored in the daily clinical practice. Our aim was to investigate this effect on Pd/Pa (distal/aortic pressure) and FFR (fractional flow reserve). 41 FFR measurements between 0.7 and 0.9 were selected. The difference in the height of the orifice and that of the sensor was defined in mm on the basis of 3D coronary reconstruction. Resting Pd/Pa and FFR were adjusted by subtracting the hydrostatic pressure gradient from the distal pressure. Height measurements were also performed from 2D lateral projections for each coronary segment (n = 305). In case of the LAD, each segment was located higher (proximal: - 13.69 ± 5.4; mid: - 46.13 ± 6.1; distal: - 56.80 ± 7.7 mm), whereas for the CX, each segment was lower (proximal: 14.98 ± 8.3; distal: 28.04 ± 6.3 mm) compared to the orifice. In case of the RCA, the distances from the orifice were much less (proximal: - 6.39 ± 2.9; mid: - 6.86 ± 7.0; distal: 17.95 ± 6.6 mm). The effect of these distances on pressure ratios at 100 Hgmm aortic pressure was between - 0.044 and 0.023. The correction for height differences changed the interpretation of the measurement (negative/positive result) in 5 (12%) and 11 (27%) cases for the FFR (cut-off value at 0.80) and the resting Pd/Pa (cut-off value at 0.92), respectively. The clinical implementation of hydrostatic pressure calculation should be considered during intracoronary pressure measurements. A correction for this parameter may become crucial in case of a borderline significant coronary artery stenosis, especially in distal coronary artery segments.


Assuntos
Pressão Arterial , Cateterismo Cardíaco , Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Idoso , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Angiografia Coronária , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Pressão Hidrostática , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Transdutores de Pressão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...